rTMS of the dorsomedial prefrontal cortex for major depression: safety, tolerability, effectiveness, and outcome predictors for 10 Hz versus intermittent thetaburst stimulation

N, Bakker; S, Shahab; P, Giacobbe; DM, Blumberger; ZJ, Daskalakis; SH, Kennedy; J, Downar
Abstract:
BACKGROUND: Conventional rTMS protocols for major depression commonly employ stimulation sessions lasting >30 min. However, recent studies have sought to improve costs, capacities, and outcomes by employing briefer protocols such as theta burst stimulation (iTBS). OBJECTIVE: To compare safety, effectiveness, and outcome predictors for DMPFC-rTMS with 10 Hz (30 min) versus iTBS (6 min) protocols, in a large, naturalistic, retrospective case series. METHODS: A chart review identified 185 patients with a medication-resistant major depressive episode who underwent 20-30 sessions of DMPFC-rTMS (10 Hz, n = 98; iTBS, n = 87) at a single Canadian clinic from 2011 to 2014. RESULTS: Clinical characteristics of 10 Hz and iTBS patients did not differ prior to treatment, aside from significantly higher age in iTBS patients. A total 7912 runs of DMPFC-rTMS (10 Hz, 4274; iTBS, 3638) were administered, without any seizures or other serious adverse events, and no significant differences in rates of premature discontinuation between groups. Dichotomous outcomes did not differ significantly between groups (Response/remission rates: Beck Depression Inventory-II: 10 Hz, 40.6%/29.2%; iTBS, 43.0%/31.0%. 17-item Hamilton Rating Scale for Depression: 10 Hz, 50.6%/38.5%; iTBS, 48.5%/27.9%). On continuous outcomes, there was no significant difference between groups in pre-treatment or post-treatment scores, or percent improvement on either measure. Mixed-effects modeling revealed no significant group-by-time interaction on either measure. CONCLUSIONS: Both 10 Hz and iTBS DMPFC-rTMS appear safe and tolerable at 120% resting motor threshold. The effectiveness of 6 min iTBS and 30 min 10 Hz protocols appears comparable. Randomized trials comparing 10 Hz to iTBS may be warranted.
Patologie/Applicazioni:
Anno:
2015
Tipo di pubblicazione:
Articolo
Parola chiave:
depressione; theta burst; corteccia prefrontale
Testata scientifica:
Brain Stimulation
DOI:
10.1016/j.brs.2014.11.002

La nostra storia

GEA soluzioni si affaccia nel 2013 al mercato della strumentazione medicale di alto livello tecnologico ma la sua storia parte da più lontano, clicca qui per approfondire.  

GEA SOLUZIONI SRL
via Issiglio 95/10, Torino
Tel.: 011 5821948 / 011 4463853
Fax: 011 0433281
Email: info @ geasoluzioni.it

P. IVA IT11696920013
REA TO1233648

Tutti i prodotti esposti sul sito geasoluzioni.it con relativi sottodomini ed aventi la natura di dispositivi medici, dispositivi medico diagnostici, presidi medico chirurgici, medicazioni per uso esterno, nonché tutti i contenuti del sito www.geasoluzioni.it (testi, immagini, foto, disegni, allegati, descrizioni e quant’altro) non hanno carattere né natura di pubblicità. Tutti i contenuti devono intendersi e sono di natura esclusivamente informativa e volti esclusivamente a portare a conoscenza dei clienti o dei potenziali clienti in fase di pre-acquisto i prodotti venduti da GEA soluzioni s.r.l. attraverso la rete. Nessun contenuto delle pagine del sito deve essere inteso come materiale pubblicitario, teso ad influenzare in qualsivoglia maniera una decisione di acquisto.

EU-Cookies

Copyright © 2024 GEA SOLUZIONI SRL. Tutti i diritti riservati.

Search