Precuneus magnetic stimulation for Alzheimer’s disease: a randomized, sham-controlled trial

Koch, G.; Casula, E. P.; Bonnì, S.; Borghi, I.; Assogna, M.; Minei, M.; Pellicciari, M. C.; Motta, C.; D’Acunto, A.; Porrazzini, F.; Maiella, M.; Ferrari, C.; Caltagirone, C.; Santarnecchi, E.; Bozzali, M.; Martorana, A.
Abstract:
Repetitive transcranial magnetic stimulation (rTMS) is emerging as a non-invasive therapeutic strategy in the battle against Alzheimer’s disease. Alzheimer’s disease patients primarily show alterations of the default mode network for which the precuneus is a key node. Here, we hypothesized that targeting the precuneus with TMS represents a promising strategy to slow down cognitive and functional decline in Alzheimer’s disease patients. We performed a randomized, double-blind, sham-controlled, phase 2, 24-week trial to determine the safety and efficacy of precuneus stimulation in patients with mild-to-moderate Alzheimer’s disease. Fifty Alzheimer’s disease patients were randomly assigned in a 1:1 ratio to either receive precuneus or sham rTMS (mean age 73.7 years; 52% female). The trial included a 24-week treatment, with a 2-week intensive course in which rTMS (or sham) was applied daily five times per week, followed by a 22-week maintenance phase in which stimulation was applied once weekly. The Clinical Dementia Rating Scale–Sum of Boxes was selected as the primary outcome measure, in which post-treatment scores were compared to baseline. Secondary outcomes included score changes in the Alzheimer’s Disease Assessment Scale–Cognitive Subscale, Mini-Mental State Examination and Alzheimer’s Disease Cooperative Study–Activities of Daily Living scale. Moreover, single-pulse TMS in combination with EEG was used to assess neurophysiological changes in precuneus cortical excitability and oscillatory activity. Our findings show that patients that received precuneus repetitive magnetic stimulation presented a stable performance of the Clinical Dementia Rating Scale–Sum of Boxes score, whereas patients treated with sham showed a worsening of their score. Compared with the sham stimulation, patients in the precuneus stimulation group also showed also significantly better performances for the secondary outcome measures, including the Alzheimer’s Disease Assessment Scale–Cognitive Subscale, Mini-Mental State Examination and Alzheimer’s Disease Cooperative Study–Activities of Daily Living scale. Neurophysiological results showed that precuneus cortical excitability remained unchanged after 24 weeks in the precuneus stimulation group, whereas it was significantly reduced in the sham group. Finally, we found an enhancement of local gamma oscillations in the group treated with precuneus stimulation but not in patients treated with sham. We conclude that 24 weeks of precuneus rTMS may slow down cognitive and functional decline in Alzheimer’s disease. Repetitive TMS targeting the default mode network could represent a novel therapeutic approach in Alzheimer’s disease patients.
Patologie/Applicazioni:
Anno:
2022
Tipo di pubblicazione:
Articolo
Parola chiave:
TMS; Alzheimer
Testata scientifica:
Brain
Nota:
La pubblicazione descrive il trattamento con rTMS di pazienti con malattia di Alzheimer. Il protocollo prevede 32 sessioni di stimolazione di cui 10 (1 al giorno) nelle prime due settimane e successivamente 22 sedute 1 alla settimana per 22 settimane. Lo studio in doppio cieco ha evidenziato una stabilità nel tempo dei punteggi risultanti da diverse scale dedicate alla valutazione cognitiva nei pazienti trattati con stimolazione reale rispetto ai pazienti trattati con stimolazione sham che hanno invece evidenziato un peggioramento dello scoring
DOI:
https://doi.org/10.1093/brain/awac285
Hits: 1225

La nostra storia

GEA soluzioni si affaccia nel 2013 al mercato della strumentazione medicale di alto livello tecnologico ma la sua storia parte da più lontano, clicca qui per approfondire.  

GEA SOLUZIONI SRL
via Spalato 72/A, Torino
Tel.: 011 5821948 / 011 4463853
Fax: 011 0433281
Email: info @ geasoluzioni.it

P. IVA IT11696920013
REA TO1233648

EU-Cookies

Copyright © 2024 GEA SOLUZIONI SRL. Tutti i diritti riservati.

Search